OmniCure R2000Plus UV Radiometer

OmniCure R2000Plus UV Radiometer

The OmniCure® R2000Plus UV Radiometer is the next-generation OmniCure UV measurement solution designed to deliver accurate and repeatable optical power and irradiance measurements for UV curing applications. Building on the R2000, the R2000Plus combines measurement equivalency with a modern graphical interface, USB-C connectivity, rechargeable battery operation, integrated data logging, and enhanced process control features. These capabilities help manufacturers maintain consistent curing performance, improve productivity, and simplify system calibration. The enhanced ergonomic design and large backlit LCD display provide flexibility for both handheld and tabletop use.

The OmniCure R2000Plus is compatible with additional custom sensors, including the OmniCure UV Cure Ring and OmniCure UV Cure Site Radiometer, to provide accurate process control for precision manufacturing. By enabling the output power from the Cure Ring to be measured directly at the cure site, the UV Cure Ring Radiometer helps ensure an accurate and repeatable bonding process.

The OmniCure UV Cure Site Radiometer provides precise process control by measuring the output power of a light guide or optical accessory directly at the bonding site. It measures the irradiance delivered to the substrate or joint, allowing users to more accurately monitor and control the curing process.

FeatureSpecification
Wavelength Range250 nm - 1 µm (with suitable calibration)
Maximum RangePower: 10 mW - 12W Irradiance: 5 mW/cm² - 60 W/cm²
Resolution0.01 mW to 0.1W depending on measurement range
Accuracy±5% maximum, ±0.200 W/cm²
Auto-rangingAutomatic range selection for both Power and Irradiance measurements to maximize displayed resolutionand precision
BatteryRechargeable Li-ion Battery
FunctionsPower Measurement, Irradiance Measurement, Relative Mode, Absolute Mode, One-Button S-Series Calibration, Data Logging, Supervisor Mode, Automatic Light Guide Detection, External Sensor Support, USB-C & RS-232 Communication, Firmware Upgrade Capability
Spectral Range300-600 nm
Calibration Range320-500 nm
Dynamic Range83 mW to 2.5W
CalibrationTraceable to the SI units of Irradiance
ConnectivityUSB-C, RS-232, Mini-DIN External Sensor Port
CertificationsCE marked: complies with IEC, Canadian and US Standards, RoHS compliant
Dimensions (L x W x H)7.75 × 4.5 × 2.5 in (197 × 114 × 64 mm)
Weight1.32 lb (600 g)
Warranty1 year

  • Maintain process control and save setup time by calibrating multiple OmniCure S2000 Series systems to a preferred irradiance set point.

  • Achieve accurate wideband optical measurements with proprietary OmniCure detector technology.

  • Virtually eliminate beam profile dependence and significantly improve measurement accuracy through the proprietary OmniCure optical interface.

  • Support statistical process control through access to calibration data stored on the R2000Plus unit.

  • Store, review, and download measurement data using the integrated data log and PC Control Software.

  • Access measurements, calibration functions, settings, and data logs easily through a large, backlit LCD display and intuitive user interface, helping improve usability and reduce operator errors.

  • Connect to a PC and charge the battery via dual USB-C ports, while the rechargeable lithium-ion battery provides added convenience for everyday operation.

  • Support a wide range of application requirements with optional accessories, including the OmniCure Cure Ring and Cure Site Detectors.

FeatureSpecification
Wavelength Range250 nm - 1 µm (with suitable calibration)
Maximum RangePower: 10 mW - 12W Irradiance: 5 mW/cm² - 60 W/cm²
Resolution0.01 mW to 0.1W depending on measurement range
Accuracy±5% maximum, ±0.200 W/cm²
Auto-rangingAutomatic range selection for both Power and Irradiance measurements to maximize displayed resolutionand precision
BatteryRechargeable Li-ion Battery
FunctionsPower Measurement, Irradiance Measurement, Relative Mode, Absolute Mode, One-Button S-Series Calibration, Data Logging, Supervisor Mode, Automatic Light Guide Detection, External Sensor Support, USB-C & RS-232 Communication, Firmware Upgrade Capability
Spectral Range300-600 nm
Calibration Range320-500 nm
Dynamic Range83 mW to 2.5W
CalibrationTraceable to the SI units of Irradiance
ConnectivityUSB-C, RS-232, Mini-DIN External Sensor Port
CertificationsCE marked: complies with IEC, Canadian and US Standards, RoHS compliant
Dimensions (L x W x H)7.75 × 4.5 × 2.5 in (197 × 114 × 64 mm)
Weight1.32 lb (600 g)
Warranty1 year

  • Maintain process control and save setup time by calibrating multiple OmniCure S2000 Series systems to a preferred irradiance set point.

  • Achieve accurate wideband optical measurements with proprietary OmniCure detector technology.

  • Virtually eliminate beam profile dependence and significantly improve measurement accuracy through the proprietary OmniCure optical interface.

  • Support statistical process control through access to calibration data stored on the R2000Plus unit.

  • Store, review, and download measurement data using the integrated data log and PC Control Software.

  • Access measurements, calibration functions, settings, and data logs easily through a large, backlit LCD display and intuitive user interface, helping improve usability and reduce operator errors.

  • Connect to a PC and charge the battery via dual USB-C ports, while the rechargeable lithium-ion battery provides added convenience for everyday operation.

  • Support a wide range of application requirements with optional accessories, including the OmniCure Cure Ring and Cure Site Detectors.

Close