pco.edge 5.5 CLHS sCMOS Camera
The pco.edge 5.5 is a high resolution cooled sCMOS camera utilizing a CLHS interface and 10G FOL (Camera Link HS) to allow direct processing of large data transfers via a computer making it easy to securely bridge distances of up to 10 km. This camera is equipped with a 16-bit scientific CMOS sensor for capturing crisp images and precise measurements. The pco.edge 5.5 camera also comes with an option to upgrade with a water cooling system.
| Sensor Technology | sCMOS FSI |
| Resolution (H x V) | 2560 x 2160 |
| Pixel Size (H x V) | 6.5 x 6.5 |
| Sensor Diagonal | 21.8 mm |
| Peak Quantum Efficiency | 60.0 % |
| Peak Quantum Efficiency Wavelength | 600.0 nm |
| Global Shutter | true |
| Rolling Shutter | true |
| Global Reset | true |
| Operational Modes |
Slow Scan: Rolling Shutter Slow Scan: Global Reset Fast Scan: Rolling Shutter Fast Scan: Global Reset Fast Scan: Global Shutter |
| Readout Noise RMS |
1.4 e- 1.4 e- 1.5 e- 1.5 e- 2.5 e- |
| Readout Noise Median |
1.0 e- 1.0 e- 1.1 e- 1.1 e- 2.2 e- |
| Fullwell Capacity | 30000 e- |
| Dynamic Range |
30000:1 30000:1 27000:1 27000:1 13500:1 |
| Dynamic Range (log) |
90.0 dB 90.0 dB 89.0 dB 89.0 dB 83.0 dB |
| Dark Current |
0.6 e-/s 0.6 e-/s 0.6 e-/s 0.6 e-/s 0.9 e-/s |
| Sensor Temperature (Dark Current Reference) | 7.0 °C |
| Frame rate (Full Sensor) |
33.0 fps 33.0 fps 100.0 fps 100.0 fps 50.0 fps |
| Dynamic Range A/D Converter | 16 bit |
| Thermo Electric Cooling | true |
| Forced Air | true |
| Liquid Cooling | false |
| Data Interface | Camera Link HS FOL |
| Included Lens Mount |
C-Mount F-Mount |
| Width | 70.0 mm |
| Length | 123.0 mm |
| Weight (kg) | 0.8 |
| Height | 76.0 mm |
| Part Number | 85108072201 |
- Bright-field microscopy
- Fluorescence microscopy
- Digital pathology
- Single molecule localization microscopy (SMLM) – PALM, STORM, dSTORM, GSDIM
- Lightsheet fluorescence microscopy (LSFM)
- Structured illumination microscopy (SIM)
- Calcium imaging
- Förster resonance energy transfer (FRET)
- Fluorescence recovery after photobleaching (FRAP)
- High-speed bright-field ratio imaging
- High throughput screening
- High content screening
- Biochip reading
- Total internal reflection microscopy (TITF)
- Spinning disk confocal microscopy
- 3D metrology
- Ophthalmology
- Photovoltaic inspection
- Industrial quality inspection
- Wafer inspection
- Image intensifier imaging
- Lucky astronomy
- Disaster recovery
- Tunnel inspection
- Particle tracking velocimetry (PTV)




| Sensor Technology | sCMOS FSI |
| Resolution (H x V) | 2560 x 2160 |
| Pixel Size (H x V) | 6.5 x 6.5 |
| Sensor Diagonal | 21.8 mm |
| Peak Quantum Efficiency | 60.0 % |
| Peak Quantum Efficiency Wavelength | 600.0 nm |
| Global Shutter | true |
| Rolling Shutter | true |
| Global Reset | true |
| Operational Modes |
Slow Scan: Rolling Shutter Slow Scan: Global Reset Fast Scan: Rolling Shutter Fast Scan: Global Reset Fast Scan: Global Shutter |
| Readout Noise RMS |
1.4 e- 1.4 e- 1.5 e- 1.5 e- 2.5 e- |
| Readout Noise Median |
1.0 e- 1.0 e- 1.1 e- 1.1 e- 2.2 e- |
| Fullwell Capacity | 30000 e- |
| Dynamic Range |
30000:1 30000:1 27000:1 27000:1 13500:1 |
| Dynamic Range (log) |
90.0 dB 90.0 dB 89.0 dB 89.0 dB 83.0 dB |
| Dark Current |
0.6 e-/s 0.6 e-/s 0.6 e-/s 0.6 e-/s 0.9 e-/s |
| Sensor Temperature (Dark Current Reference) | 7.0 °C |
| Frame rate (Full Sensor) |
33.0 fps 33.0 fps 100.0 fps 100.0 fps 50.0 fps |
| Dynamic Range A/D Converter | 16 bit |
| Thermo Electric Cooling | true |
| Forced Air | true |
| Liquid Cooling | false |
| Data Interface | Camera Link HS FOL |
| Included Lens Mount |
C-Mount F-Mount |
| Width | 70.0 mm |
| Length | 123.0 mm |
| Weight (kg) | 0.8 |
| Height | 76.0 mm |
| Part Number | 85108072201 |
- Bright-field microscopy
- Fluorescence microscopy
- Digital pathology
- Single molecule localization microscopy (SMLM) – PALM, STORM, dSTORM, GSDIM
- Lightsheet fluorescence microscopy (LSFM)
- Structured illumination microscopy (SIM)
- Calcium imaging
- Förster resonance energy transfer (FRET)
- Fluorescence recovery after photobleaching (FRAP)
- High-speed bright-field ratio imaging
- High throughput screening
- High content screening
- Biochip reading
- Total internal reflection microscopy (TITF)
- Spinning disk confocal microscopy
- 3D metrology
- Ophthalmology
- Photovoltaic inspection
- Industrial quality inspection
- Wafer inspection
- Image intensifier imaging
- Lucky astronomy
- Disaster recovery
- Tunnel inspection
- Particle tracking velocimetry (PTV)




Subscribe Now!
Floating Web Forms block
Join the PCO Circular newsletter for early access to insights on our high‑performance imaging cameras. Receive the latest application notes, expert webinars, technical articles, educational videos, product innovations, and industry events designed for scientific, microscopy, research, and industrial imaging applications.